Herunterladen Inhalt Inhalt Diese Seite drucken

glass 1989 Infinity Bedienungs- & Wartungsanleitung Seite 54

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

key. Timeout 20'. By touching again key
2 it turns off.
CONTROL OF WATER
TEMPERATURE (heating/chilling)
The temperature of the water can be
EN
read in heater every ogni 30minutes
Selection of water temperature
set point
At the first touch of either the plus "+"
or "-" key, the display shows the current
value of the set point and the two keys
are lightened; from the second touch
onwards of either key, the value will
increase or decrease correspondingly.
If the "+" and "-" keys remain untouched
for 6s, or a different key is touched, the
display reverts to showing the current
temperature, and the new set point is
stored.
The characteristics of this parameter are:
• range of possible values in heating
mode: 15 - 40 °C
• range of possible values in chilling: 10
- 40 °C
• setting increments: 1°C
• Default value 35°C
• value at power-up: system retains the
last set point saved.
Heating mode
The controller activates the heater so as
to maintain the temperature of the water in
the tub at the level of the set point, ±1 °C.
When the heating function is activated,
the following steps take place:
• verification of water flow
• activation of heater.
• The first decimal point (nearest the left)
blinks in the display
On deactivation of the heating function:
• the heater is powered off;
• The decimal point is cleared from the
display
N.B: he AUX output can be used to
control a heat exchanger in combination
with an electric heater.
Chilling mode, AUX output
In an operating mode that utilizes an
electric heater together with a heat
pump for chilling, the controller activates
the heat pump (AUX output) to chill the
water, in such a way that it can be kept at
a selected low temperature (set point) of
+1.5 °C/-1 °C.
CHROMOTHERAPY FUNCTION
The
LIGHT
3
chromotherapy light box.
If serial transmission is interrupted the
message "CO" appears in the display.
Chromotherapy function can be activated
also when spa is empty.
With light off
On touching the key, chromotherapy is
activated in colour sequence mode; the
key lights up and blinks.
The change from one colour to the next
occurs every 15 seconds, fading in and
out. Touching the key a second time,
the function changes to "fixed colour".
The sequence is broken, and the colour
showing at the moment of touching the
key remains active.
"Fixed colour" mode
The light remains permanently on one
colour. The colour changes each time the
key is touched, switching to the next one,
but always in "fixed" mode, one colour at
a time.
Switching off the light
Touching and holding the LIGHT key for
at least 2 seconds, the light source will
deactivate.
ECONO FUNCTION
With the ECONO function, energy can
be saved by maintaining the pool water
at 10°C below the temperature selected
by the user. In any event, the minimum
permissible water temperature is 15 °C.
The user can control this function either
with the ECONO button on the remote
control, or by way of a combination of
controls on the keypad:
• One touch of either the PLUS or MINUS
key to view the current temperature set
14
key
controls
a

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis