possibility of electric shock. Disconnect power to the spa until the fault has been
identified and corrected.
NOTE: Failure to wait 30 seconds before resetting the GFCI may cause the spa's
Power Indicator (on the control panel) to blink. If this occurs, repeat the GFCI
test procedure.
• Install the spa so proper drainage is provided for the compartment containing the
EN
electrical components.
DANGER: RISK OF ELECTRICAL SHOCK
• Install spa at least 1.5 m from all metal surfaces. A spa may be installed within 1.5
m of a metal surface if each metal surface is permanently connected solid copper
conductor attached to the wire equipotential connector on the terminal box that is
provided for this purpose.
• Do not permit any electrical appliances, such as a light, telephone, radio, or television
within 1.5 m of a spa. Failure to maintain a safe distance may result in death, or
serious personal injury due to electrocution, if the appliance should fall into the spa.
• Install your spa in such a way that drainage is away from the electrical compartment
and from all electrical components.
DO:
• Be sure your spa is connected to the power supply correctly - use a licensed electrical
contractor.
• Disconnect the spa from the power supply before draining the spa or servicing the
electrical components.
• Test the Ground Fault Circuit Interrupter(s) before each use.
DON'T:
• Use the spa with the equipment compartment door removed.
• Place electrical appliances within 1.5m of the spa.
• Use an extension cord to connect the spa to its power source. The cord may not be
properly grounded and the connection is a shock hazard. An extension cord may
cause a voltage drop, which will cause overheating of the jet pump motor and motor
damage.
• Attempt to open the electrical control box. There are no user serviceable parts inside.
The product's supporting structure is metallic. An efficient ground system is therefore
required, with sensitivity meeting the relevant standards.
GROUNDWIRE.
The ground wire must be connected and fixed permanently to the electrical system.
EQUIPOTENTIAL CONNECTION.
The equipment must be connected to the equipotential system of the room and
duly fastened to its terminal to be found in the product.