START-UP SEQUENCE

1
Connect the gun to a clean, moisture and oil free air supply using a conductive hose of at least
8mm I.D.
2
Adjust packing nut
(see packing adjustment instructions).
3
Mix coating material to Manufacturer's instructions and strain material.
4
Turn fluid adjusting knob (11) clockwise to prevent fluid needle movement.
5
Turn spreader valve adjusting knob (5) counter clockwise to fully open.
6
Adjust inlet air pressure if required.
7
Turn fluid adjusting knob counter clockwise until first thread shows.
8
Test spray. If the finish is too dry, reduce airflow by reducing air inlet pressure.
9
If finish is too wet, reduce fluid flow by turning fluid adjusting knob clockwise. If atomisation is
too coarse, increase air inlet pressure. If too fine, reduce inlet pressure.
10
The pattern size can be reduced by turning spreader valve knob clockwise.
11
Hold gun perpendicular to surface being sprayed. Arcing or tilting may result in uneven coating.
12
The recommended spray distance is 150-200mm.
13
Spray edges first. Overlap each stroke a minimum of 75%. Move gun at a constant speed.
14
Always turn off air supply and relieve pressure when gun is not in use.