Setting of the end positions

4. Setting of the end positions

4.1. Delivery status

In the SELVE delivery status no end positions or transmitters are programmed into the radio
motor!

4.2. Setup functions

The end positions setting of a SELVE radio motor is possible via:
• the setting switch for radio motors (item no. 290109 or 291009)
• any standard switch (in automatic mode)
• any standard commeo transmitter.

4.3. Mechanic requirements

For operating the SEE-com security springs must be used.
If the motor is supposed to move against the stop in the upper end position, a stable end stop
must be installed!
If the motor is set in automatic setup-mode, a limit must be installed for the lower switchoff
position (e.g. windowsill) for the shutter to run against.

4.4. Selection table for settings

Setup-mode/end positions in operation
Automatic setup- mode
bottom position, top stop/release
Manual setup -mode
bottom position, bottom stop
Manual setup- mode
bottom position, top stop/release
Setting switch
4.5.1. (page 40)
4.5.2. (page 41)
4.5.3. (page 42)
38
commeo radio
5.2.1. (page 46)
5.2.2. (page 47)
5.2.3. (page 48)

Werbung