Herunterladen Inhalt Inhalt Diese Seite drucken

Qlima Eleonora 74-2 S-line Gebrauchsanweisung Seite 158

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
4
158
man_Eleonora 74-2 S-line ('22) V1.indd 158
man_Eleonora 74-2 S-line ('22) V1.indd 158
Stove goes out.
Pressure sensor/switch is
The alert shown
defective
is "AlAr dEp" and
The exhaust/flue/chimney is
one or both of
blocked
the LEDs ALF and
ALC on the con-
Electronic printed circuit
trol panel are lit.
board is defective.
Excessive flue length
Unfavourable weather con-
ditions
Stove is overheating
The room air recirculation
blower is defective
Temporary power outage
Safety thermostat is defective
Stove goes out.
Flue gas temperature sensor is
"AlAr Sond" is
defective.
shown in the
The wiring to the flue gas
display
sensor is loose.
Display shows
The stove has been switched
"Cool Fire"
off manually, by the timer
mode or the save mode.
The stove is in cooling down
phase.
Power failure
Display shows
The flue blower is defective
"Alar fan fail"
or the printed circuit board
cannot measure its speed.
Replace the pressure switch. Only to be done by a
Qlima-approved technician
Have the exhaust/flue/chimney cleaned immedi-
ately by an approved chimney sweep. Contact an
approved chimney sweep.
Replace the electronic printed circuit board. Only
to be done by a Qlima-approved technician
Consult a flue specialist to check whether the flue
complies with the law. Consult a Qlima-approved
technician to check whether the flue is suitable for
the stove.
Strong winds can cause negative pressure in the
flue. Check and restart the stove.
Room temperature too low. Open doors to other
rooms. If the problem persists, contact a Qlima-ap-
proved technician.
The safety thermostat on the stove has been
triggered. Let the stove cool down, then reset the
safety thermostat by removing the protective cap
(figure 38) and pressing the reset button (figure
39).
Replace the blower. Only to be done by a Qli-
ma-approved technician
A power cut when the stove is in operation can
cause the interior to overheat. Allow the heater to
cool down and restart it.
Replace the safety thermostat. Only to be done by
a Qlima-approved technician
Replace the sensor. Only to be done by a Qlima-ap-
proved technician
Fix the wiring. Only to be done by a Qlima-ap-
proved technician
This is not an error; the cooling down phase stops
automatically when the stove has cooled down
sufficiently.
After the electricity supply has been restored, the
stove will start in the cooling down phase. The
stove can then be started up again.
Either the flue blower, the printed circuit board
or the speed sensor is defective, or the wiring is
damaged or loose. Fix the defect. Only to be done
by a Qlima-approved technician
03-05-2022 16:27
03-05-2022 16:27

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis