Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
4.
ECONO
SEND
TURBO
AUTO
ON 1
OFF 1
ON 2
CANCEL
OFF 2
4
146
man_Eleonora 74-2 S-line ('22) V1.indd 146
man_Eleonora 74-2 S-line ('22) V1.indd 146
5.
The procedure for changing the heat output setting is now complete.
6.
The desired heat output can also be set using the remote control. See sec-
tion 4.8 for instructions on using the remote control.

4.6 SAVE MODE

When this mode is active, the stove will automatically switch off as soon as the
room temperature - plus the set differential temperature - has been reached. The
stove will automatically switch itself off as soon as the room temperature - plus the
set differential temperature - has been reached.
The Save mode can only be used when the stove is not in timer mode.
SWITCHING ON SAVE MODE
1.
Switch the stove off.
2.
Push button 1 and then repeatedly push button 3 until UT04 appears in the
display.
3.
Push button 2. The value 1 will appear in the display. Now hold down button
2 until the value A9 appears in the display.
4.
By pushing on button 3 again, the display will show Pr01. Push button 3
repeatedly until Pr28 appears in the display, alternating with the text "OFF"
or a numeric value between 1 and 15.
5.
If "OFF" is shown on the display, then SAVE MODE is off. This can be switched
on with buttons 1 or 2. By pushing buttons 1 or 2 the differential tempera-
ture, which can be set from 1ºC to 15ºC, will appear in the display.
6.
Select the desired differential value and then push button P3 to save the
setting.
7.
The stove is now in Save mode and can be started up again.
DIFFERENTIAL TEMPERATURE
The differential temperature is the difference in degrees Celsius in relation to the
set temperature. Example: The set temperature is 20ºC and the set differential
temperature is 2ºC. The stove will now go out at a room temperature of 22ºC and
start up again at a temperature of 18ºC.
SWITCHING OFF SAVE MODE
1.
Switch the stove off and repeat the above actions until "OFF" appears in the
display.
2.
Then push button 3.
3.
Save mode is now switched off.
To prevent excessive start-ups and shut-downs and extra wear on various parts, it
is recommended not to set the differential temperature at less than 2ºC or higher
than 4ºC.
4.7 STANDARD SHUT-DOWN
The stove can be switched off by pressing button 3 until "OFF" appears in the dis-
play. During the shutdown phase, the supply of wood pellets to the combustion
chamber is stopped and the room air circulation blower is switched off. The smoke
extraction blower will continue to run for a short time, switching off after the
cooling-down phase.
03-05-2022 16:27
03-05-2022 16:27

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis