Herunterladen Inhalt Inhalt Diese Seite drucken

Qlima Eleonora 74-2 S-line Gebrauchsanweisung Seite 156

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
4
156
man_Eleonora 74-2 S-line ('22) V1.indd 156
man_Eleonora 74-2 S-line ('22) V1.indd 156
Stove goes out,
The pellet hopper is empty
alarm "AlAr no
The brazier is dirty
FirE" is displayed
The auger motor is defective
Electronic printed circuit
board is defective
The temperature sensor has
not detected the minimum
temperature threshold to
initiate start-up
Not enough combustion air is
reaching the fire
Wooden pellets are not of a
good quality
Auger is blocked
15 minutes
The ignition mechanism is
after starting,
defective.
the stove displays
The temperature sensor has
the "ALARM NO
not detected the minimum
ACC" alert
temperature threshold to
initiate start-up
Outdoor temperature is too
low.
Wooden pellets are damp
Temperature sensor is defec-
tive
Electronic printed circuit
board is defective
The hopper is empty
Wooden pellets
Auger is blocked
are not reaching
the combustion
chamber
Auger motor is damaged
The hopper is empty
Fill the pellet hopper with pellets
Clean the brazier
Replace the auger motor Only to be done by a
Qlima-approved technician
Replace the printed circuit board Only to be done
by a Qlima-approved technician
Empty the combustion chamber and start again
if the problem recurs. Contact a Qlima-approved
technician if the problem persists.
Check the following (can be done by end-user):
- Possible obstruction of the combustion air inlet
pipe at the rear of the stove. Clean the fresh air
inlet pipe.
- Combustion chamber grate slots blocked and/or
too much ash or dirt in combustion chamber and
requires cleaning. Only to be done by a Qlima-ap-
proved technician.
- Heat exchanger in the stove is dirty. Clean the
heat exchanger.
Try better quality pellets
Unplug the stove at the mains socket. Remove
the protective grill from the hopper and clean
the hopper. Carefully clean the visible parts of the
auger. Refit the protective grille and start again.
Contact a Qlima-approved technician if the prob-
lem persists.
Replace the ignition mechanism. Only to be done
by a Qlima-approved technician
Empty the combustion chamber and start again
if the problem recurs. Contact a Qlima-approved
technician if the problem persists.
Empty the combustion chamber and start again.
Contact a Qlima-approved technician if the prob-
lem persists.
Only use fry wooden pellets.
Replace the sensor. Only to be done by a Qlima-ap-
proved technician
Replace the electronic printed circuit board. Only
to be done by a Qlima-approved technician
Fill the pellet hopper.
Unplug the stove at the mains socket. Remove
the protective grill from the hopper and clean
the hopper. Carefully clean the visible parts of the
auger. Refit the protective grille and start again.
Contact a Qlima-approved technician if the prob-
lem persists.
Replace the motor. Only to be done by a Qlima-ap-
proved technician
Fill the pellet hopper.
03-05-2022 16:27
03-05-2022 16:27

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis