Herunterladen Inhalt Inhalt Diese Seite drucken

Setting Of The End Positions; Delivery Status; Mechanic Requirements; Setup Functions - Selve Commeo Se Pro-Rc Originalbetriebsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Setting of the end positions

EN
4. Setting of the end positions

4.1. Delivery status

In the SELVE delivery status no end positions or transmitters are programmed into
the radio motor! In this state, the motor can be operated in deadman's operation only.
Safety functions such as obstacle detection are deactivated at delivery and will only
become active after both end positions are set.
State at delivery is indicated by a short movement when the radio motor is connected
to power. The SE Pro­RC motor is in automatic setup­mode.

4.2. Mechanic requirements

Operating of the SE Pro­RC motor is possible with normal safety and fixing springs.
Optionally, security springs can also be used (manual setup­mode).
If the motor is supposed to move against the stop in the upper end position, a stable
end stop must be installed!
If the motor is set in automatic setup­mode, a limit must be installed for the lower
switchoff position (e.g. windowsill) for the shutter to run against.

4.3. Setup functions

The end positions setting of a SELVE radio motor is possible via:
• the setting switch for radio motors (item no. 290109 or 291009),
• any standard switch (in automatic mode),
• any standard commeo or iveo transmitter.
Further detailed information for the start-up of the drive can be found in the
original operating instruction SE Pro-RC at www.selve.de:
• Manual setup-mode (fixed points) with setting switch/switch
• Manual setup-mode (fixed points) with a commeo transmitter
• Initial operation and setting with an iveo transmitter
EN