TECHNICAL INFORMATION: main adjustment parameters.
Par.
SET
dtE
idF
MdF

TECHNICAL DOCUMENTATION INSERTED IN COUNTERS

Each counter has a yellow envelope placed inside near the serial number plate. This envelope
contains all the required technical documentation, such as:
Use and maintenance manual;
Declaration of conformity;
Quality control sheet;
Test inspection certificate;
Counter wiring diagram;
Lighting system diagram;
Manual of controller installed on electric panel (only if foreseen);
Controller parameters map (only if present);
Various documentation such as: motorised night blind instructions, electronic valve instruc-
tions,... (only if present).
Yellow
envelope
N.B.: At times, other labels with additional instructions and/or recommendations are applied to some
surfaces of the counter.
DESCRIPTION
Temperature control setting
HY
Differential
End defrost temp.
Defrost cycles interval
Maximum defrost duration
Milos 2.0 SM
Adjustment
range
Cl. M2
(+3/+5°C)
-2.0
LS÷US
5.0
0,1÷25,5
8.0
-50,0÷110,0 °C
8.0
1÷120 hours
50.0
0÷255 min
21
Cl. M1
(0/+2C)
-3.0
6.0
8.0
8.0
50.0