INSTALLATION RECOMMENDATIONS
The installation of the appliance and the refrigerant unit must only be made by the manufactur-
−
er's service personnel or similarly skilled person;
Correct positioning of cabinet;
−
> 60 mm
Make sure that the support plane is leveled for the bench to work properly to avoid unexpected
−
noise (normally the sound pressure is less than 70 DbA).
Connect the appliance to an efficient earthing system;
−
The electrical connection must be performed permanently type X or higher, with an H05VV-F ca-
−
ble or higher, or equivalent material;
Installation and the electrical connection must be performed in compliance with national and local
−
standards in force;
Leave the earth cable a few cm longer than the other cables to make sure it does not disconnect
−
if pulled;
Isolate the power circuit upstream by means of an omnipolar circuit breaker switch with a mini-
−
mum contact opening of 3 mm;
Cables for the RS485 connection, LAN network and remote light control must be considered
−
SELV circuit. The power cables must always be separated;
Wiring diagram for connection with outside condenser unit;
−
Make sure that the appliance is loaded with the refrigerant indicated on the serial number plate of
−
each counter.
ATTENTION: The arrangement and amount of products must not exceed the load limit. We also rec-
ommend making sure that the full load is not excessive for the structure of the counter. The following
are the approximate capacity values of the shelves. Respect these indications as much as possible:
Max capacity of bottom surface
120 Kg x Surface 625
N.B.: the maximum weight loaded on the upright display case must not exceed 6 Kg for the 1250 mm
module, divided between the cover glass and middle shelf, if present.
Max capacity cover glass + middle shelf
6 Kg x Mod. 1250
10