8 Installation
Drilling distances for external cover PP 45 AK
(plastic)
CAUTION Exercise caution when hand-
ling housing parts with sharp edges, e.g.
stainless steel external covers
Wear protective gloves.
1. Once the external plastering is complete, re-
move the plaster protective cover.
F
Front cover
G
Housing
2. Take off the front cover of external cover's
housing.
3. Align housing horizontally and centred with
wall sleeve, mark 4 fixing holes, position dow-
els and screw down housing to exterior wall
with 4 screws. Suitable mounting material is to
be provided by the customer.
G
Housing
S1
Sealing strip (silicone)
4. Seal bottom third of spaces between wall
sleeve and housing with permanently elastic
and weatherproof sealant e.g. sealing strip
(silicone).
5. Press front cover onto housing so it engages
all the way round. Place external cover (stain-
less steel/white/black) on the housing and
tighten the pre-assembled screws.
6. Seal front cover to exterior wall with perman-
ently elastic and weatherproof sealant (arrows
S2). Suitable sealing material is to be supplied
by the customer.
8.2.3 Installation of external covers PPB 30 AK
and PPB 30 AE / PPB 30 AW / PPB 30 AS
(once exterior wall is fully plastered)
Position of the external cover and wall sleeve
→ Use drilling template!