Network interface
8
Technical data (continued)
8.7

Approvals and designations

Additional information on directives, approvals and
standards can be found at www.balluff.com on
the product page.
8.7.1
CE
The CE Mark verifies that our products
meet the requirements of the current EU
Directive.
8.7.2
UL
Cleaning
Clean the product only with dry cloth or cloth dampened
only with water!
UL requirements
File
Classification
Ambient
temperature
The power supply has to be an isolated type or SELV type.
Power ratings
Power input, nominal
rated voltage 24 V DC
Power output, nominal
rated voltage 24 V DC
Digital input, nominal
rated voltage 24 V DC
Digital output, nominal
rated voltage 24 V DC
14
english
E319845
Type 1
+45 °C
– 130 mA maximum
consumption
– 16 A including all output loads
– max. 16 A
– max. 30 mA/pin (point)
Class A IO-Link Port
– 0.5 A/port (point) Pilot Duty
– 4 A/port (point) Resistive /
General use
– 16 A or less per device
Cable sizes
Power supply cable:
Listed or R/C cable (CYJV2/8) with M12 female thread and
L-coded plug rated 24 V minimum, 16 A minimum for all
models. S, SJ, SO, ST, SV, or R/C (AVLV2) listed cable
marked or specified on the UL Style Page as suitable for
external connections, rated 300 V minimum, 14 AWG
minimum, unless marked with the maximum load current
and overcurrent protection for the cable in accordance
with the table below.
Mains connection cable:
Listed or R/C cable (CYJV2/8) with an M12 L-coded
threaded plug and a voltage rating of at least 24 V and at
least 16 A for all models. Listed S, SJ, SO, ST, SV or R/C
cable (AVLV2) marked or specified on the UL Style Page as
suitable for external connections, rated 300 V minimum
and 14 AWG minimum, unless marked with the maximum
load current and overcurrent protection for the cable in
accordance with the table below.
Communication cable:
Listed or R/C cable (CYJV2) with A, B, or D-coded male or
female threads, as applicable, for connection to Article 9,
M12 plug rated 24 V minimum and 1 A minimum. R/C
(AVLV2), marked or specified on the UL Style Page as
suitable for external connections, cable rated 28 AWG
minimum and 300 V minimum.
Input/output cable:
Listed or R/C (CYJV2) cable with A-coded M12 threaded
plug, minimum 24 V, minimum 2 A. R/C (AVLV2), labeled or
specified on the UL Style Page as suitable for external
connections, cable rated 300 V minimum, 24 AWG
minimum, unless the maximum load current and
overcurrent protection for the cable are specified in
accordance with the table below.
Cable
14 14 16 18 20 22 24 26 28 30
conductor
size, AWG
Overcurrent
16 12 8 5.6 5
protection
maximum
amperage
[amps]
Maximum load
16 9
8 5.6 4 2.4 1.6 0.8 0.6 0.4
[amps]
Tab. 8-1:
Cable sizes
3
2
1 0.8 0.5