Herunterladen Inhalt Inhalt Diese Seite drucken

Disassembly For Disposal For; Returns - Gemü 695 Originalbetriebsanleitung

Metall, dn 15 - 50
Vorschau ausblenden Andere Handbücher für 695:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

15.1 Disassembly for disposal
for control function 1
29
12
13
FP
695_us
Actuator top 10 is under
SA2
spring pressure!
SA1
® Risk of severe injury or death!
G
1.
Separate actuator from control medium.
2.
Remove loose compressor 3.
3.
Remove protective cap SA2.
4.
Remove optical position indicator SA1.
5.
Remove protective caps 29.
10
6.
Clamp actuator in a press.
Applied pressure too high!
® Risk of breakage of actuator
top 10!
Only use minimum required
G
pressure.
7.
For diaphragm sizes 25 and 40:
Undo and remove bolts 12 with
washers 13 between actuator top 10
and actuator base 16.
8.
Slowly release the press.
9.
Remove actuator top 10.
10. Remove spring set FP comprising 3
compression springs from actuator
base 16.

16 Returns

Clean the diaphragm valve.
G
Returns must be made with a completed
G
declaration of return (included).
If not completed, GEMÜ cannot process
credits or

repair work

but will dispose of the goods at the operator's
expense.
16
3
36 / 44
WARNING
Only open the actuator under
a press.
CAUTION

Werbung

Inhaltsverzeichnis
loading