tau K123M Installationsanleitung Seite 15

Steuerplatine fuer den getriebemotor master12q
Vorschau ausblenden Andere Handbücher für K123M:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 20
GATE OPEN
9 - 10
WARNING LIGHT
SENSITIVE
11 - 13
12 - 13
PHOTOCELLS
14 - 15
14 - 16
OPEN/CLOSE
14 - 17
PEDESTRIAN
18 - 19
2
RADIO CH
nd
20 - 21
AERIAL
22 - 23 - 24
ENCODER
25 - 26
BATTERY
POWER
FS1 - FS2
SUPPLY
MEMORIZATION PROCEDURE
WARNING: After powering the control panel, wait 2 seconds before you start performing
the adjustment operations.
Note: The gate must be equipped with the opening and closing safety stops.
When you have completed the installation procedures :
1_ bring the gate to approx. 1 m from the closing travel limit;
2_ set dip-switch no. 8 to ON;
3_ operate the automation using one of the following inputs: A/C, radio control or card button.
4_ the gate must start to close.
Note: if it opens, stop the programming procedure by resetting the electric panel (discon-
nect the power supply to the panel for at least 5 sec. and set dip-switch no. 8 to OFF); with
the control panel disconnected, exchange the motor supply wires. Restart the procedure
from point 1.
18V DC max. 3W output for supply to open and moving gate
warning light (9 = NEGATIVE - 10 = POSITIVE);
N.C. input for electromechanical sensitive edge – it cuts in
during the opening manoeuvre, locking and re-closing the
EDGE
gate by ~20 cm (11 = C.F. - 13 = COM);
N.C. photocell input - it cuts in during the closing or the open-
ing manoeuvre, see dip-switch no. 3 (12 = FOT - 13 = COM);
Note: the photocell transmitter must always be supplied
by terminals no. 5 and no. 6, since the safety system test
(phototest) is carried out on it. Without this connection,
the control unit does not work. To override the testing of
the safety system, or when the photocells are not used,
set dip-switch no. 6 to OFF.
N.C. input for STOP button – It stops the gate in any position,
STOP
temporarily inhibiting its automatic closing, if programmed
(14 = COM - 15 = STOP);
N.O. input for OPEN/CLOSE button - It commands the open-
ing and closing of the gate and its operation is controlled by
dip-switches 2 and 3 (14 = COM - 16 = A/C);
N.O. input for PEDESTRIAN button - It commands the partial
opening and closing of the gate for ~1 m of travel and its op-
eration is controlled by dip-switches 2 and 3
(14 = COM - 17 = PED);
2
radio channel output - for control of an additional automa-
nd
tion or for switching on lights, etc... (N.O. clean contact);
Warning: to connect other devices to the 2nd Radio
Channel (area lighting, pumps, etc.), use an additional
auxiliary relay (with receiver connected).
plug-in radio-receiver aerial input , for 40.665 MHz receivers
only (20 = SIGNAL - 21 = GROUND);
encoder supply and input (22 = BROWN positive -
23 = WHITE signal - 24 = BLUE negative);
battery 12V - 7,2Ah input;
board supply input 13.5 Vac – Powered by the toroidal trans-
former housed in the MASTER12Q motor and protected by a
fuse on the 230 Vac power supply ;
K123M
15