7.1 Cooling Unit
Cooling Unit with Mouthpiece must be free of deposits. Deposits on the inside
of the Cooling Unit are caused by steam condensate. Cleanliness is a prereq-
uisite for proper function.
X Check the Cooling Unit with Mouthpiece prior to each use.
X Clean the Cooling Unit with Mouthpiece no later than 7 days after the last
use and if deposits are visible on the inside of the Cooling Unit.
7.1.1 D isassembling the Cooling Unit
X Heat up the Cooling Unit for better disassembly, as the steam conden-
sate can be sticky.
7 C L E A N I N G / H Y G I E N E
X Pull the Cap Lock towards the
Mouthpiece.
X Pull the Cooling Unit Cap off the
Vaporizer.
X Pull the Mouthpiece out of the
Cooling Unit Cap while slightly tilting
it back and forth.
X Pull off the Mouthpiece Seal Ring.
X When cleaning the Cooling Unit Cap
in isopropyl alcohol, remove the Cap
Lock by pulling it up on one side.