Installation Procedures

Please use the standard tools according to the installation requirements.
The standard attached accessories of the units of this series refer to the packing; prepare other accessories according
to the requirements of the local installation point of our company.
1.
Choose a suitable installation location. Indoor units should be installed in places with even ventilation. The follow-
ing places should be avoided.
*
Places with high salinity (beach), high sulfureted gas (such as the thermal spring regions where copper tubes and
soft soldering are easily eroded), much oil (including mechanical oil) and steam; places where organic substance
solvent is frequently used; places where machines generate high frequency electromagnetic waves (the control
system will perform abnormally); places with high humidity releases near the door or windows (dew is easily
formed); and places where the special sprayer is frequently used.
Indoor Units
(1) The distance between wind outlet port and the ground should not be more than 2.7 m. The distance to the streets
should not be less than 2.5m.
(2) Select appropriate places for installation where the outlet air can spread to the entire house and arrange suitable
locations for connecting pipes and lines as well as the drainpipe to the outdoor.
(3) Wall construction must be strong enough to hold the weight of the unit.
(4) It is recommended to make the connecting pipe between the outdoor and indoor units and the drainpipe as short
as possible.
(5) Please read the attached installation instructions of outdoor units for regulation on filling amount of refrigerant if
necessary.
(6) Electrical appliances such as television, instruments, devices, artwork, piano, wireless equipment, and other
valuables should not be placed under the indoor unit and over 1 m away from the daylight lamp to prevent
condensate from dripping onto them and causing damage.
2.
The following steps can be taken after selecting the installation place:
Make a hole on the wall and put the connecting pipe and connecting thread into the PVC, purchased from the
local shop. With a slight downward tilt towards the exterior, the gradient should be kept at least 1/100. before
making the hole. Check if there are pipes or reinforcing steel bars at the rear of the hole. Making a hole in the
place with wires or pipes should be avoided.