Water that has passed through a back-
flow preventer is classified as undrink-
able.
High-pressure hoses, fittings and
couplings are important for machine
safety. Use only high-pressure hoses,
fittings and couplings recommended by
the manufacturer.
To ensure machine safety, use only
original replacement parts from the
manufacturer or replacement parts au-
thorised by the manufacturer.

Electrical safety:

Caution: to avoid accidents and
injuries from electric shocks:
The plug and socket of an extension
cable must be water-tight!
Unsuitable extension cables can
be dangerous as people can be
harmed by an electric shock!
Protect the electric plug connections
against moisture.
If there is a risk of flooding, fix the
plug connections in an area that is safe
from flooding.
Ensure that the mains voltage matches
the specifications on the rating plate.
The electrical installation shall be ac-
cording to national wiring rules.
Connection to the mains must be
carried out by an experienced electri-
cian and meet the requirements of
IEC 60364-1.
The device must only be connected to
a mains socket via a residual-current
circuit breaker (RCD) with a rated leak-
age current of not more than 30 mA.
Fuse: at least 13 ampere.
8
Before each use, check the equipment,
cable and plug for damage.
If the power cable for this equipment is
damaged, it must be replaced by the
manufacturer, a customer service agent
of the same or a similarly qualified per-
son in order to prevent hazards.
Do not pull the plug from the socket by
the cable. Protect the cable from heat,
oil and sharp edges.
Do not carry or fix the equipment by
the cable.
Use only extension cables that are pro-
tected from spray water and designed
for outdoor use. Always fully unroll a
cable drum before use. Check the ca-
ble for damage.
Before any work on the equipment,
during work breaks and in the case
of non-use, remove the plug from the
socket.
The cross-section of the power sup-
ply cable must not be less than
2 x 2,5 mm².
Wear sturdy footwear to protect
against electric shock.

Initial Operation

In keeping with current regulations
a pressure washer must never be
operated off the drinking water
mains supply without a controlla-
ble backflow preventer. A suitable
backflow preventer in conformity
with EN 12729 type BA must be
used.
Water that has passed through a backflow
preventer is classified as undrinkable.
A backflow preventer is available
from specialist retailers.