Select the usage parameters using the up
SET P, T, FREQ
SET TIME
OPERATION MODE
SEQ PARAM SET
RST MAINT TIME
MAX RUN TIME
USER PASS:
LANG.
SET P, T, FREQ — set pressure and temperature
(Below are the example set values for the compressor with the max. 8-bar operating pressure).
P LOAD
05.2 BAR
P ULD
08.00 BAR
FREQ P
007.0 BAR Set pressure of the frequency inverter.
T FAN
0095°C
T FAN STOP
0060°C
RAT. POWER 75.0kW
RATED SPEED 2940RPM
SET TIME
FAN DELAY:
0002S
LOAD DELAY: 0002S
IDLE DELAY:
0300S
STOP DELAY:
0005S
START DELAY: 0040S
SPEED INCR:
0625
SPEED DECR: 0625
Operational mode
RUN REMOTE/LOCAL
LOAD AUTO/MANUAL
COM: PC/BAN/GRP
COM ADDRESS: 001
20
If the compressor is ready, it switches at this pressure to loaded running.
At this pressure the compressor switches to idle running.
Switch-on temperature of the fan.
Switch-off temperature of the fan.
Rated power of the electric motor.
Rated speed of the electric motor.
Delay in overloading fan.
Delay in load run (suction valve open).
Idle run time. Suction valve closed, and main motor running.
Switch-off delay with off button. Suction valve closed, and main motor running.
Delay in restart. Drop in system pressure.
PID setting for the maximum speed increase.
PID setting for maximum speed reduction.
Switch on by remote control or locally via the control.
Loaded running/idle running automatically or manually.
Communication mode: PC / MODBUS / group.
Communication port, network address.