11 SANITIZING

Use a 200 mg/l solution of sodium hypochlorite and water (or a solution of ½ ounce of normal bleach to 1 gallon of water), or one
of the solutions commonly used to disinfect babies' feeding bottles; in this case, check that the sanitizing product is:
• authorized by your country's Ministry of Health
• suitable for use with food-making machinery
• not harmful to the materials and components of this appliance
For the directions for use and concentrations, please refer to those shown on the packaging and recommended by the
manufacturer. We recommend using the solution at the temperature of 25°C.
1. fill basin with sanitizing solution. Refer to the table for the amount of solution required, depending on daily output (Fig. 11)
2. reposition front panel
Before connecting the appliance to the mains power supply, ensure that all cables and electrical wiring are perfectly
dry.
3. connect appliance to mains power supply and switch on with luminous switch
4. operate appliance for at least 20 minutes
5. switch off appliance and disconnect from mains power supply
6. remove front panel (Fig. 10), top, and evaporator cover panel (Fig. 13)
7. remove (Fig. 6) and immerse in sanitizing solution for 30 minutes:
• overflow pipe (Fig. 11)
• ice-cube chute (2)
• sprayer bank (3) and side caps (4), after removing them from the bank
• sprayer bank feed pipes (5)
• evaporator cover panel (Fig. 13)
8. pour sanitizing solution onto both sides of the evaporator (Fig. 14) and tilting panel (7 in Fig. 15) and distribute with a stiff
brush and a brush with soft bristles
9. thoroughly rinse evaporator, tilting panel and inner basin by pouring plenty of cold water over them
10. thoroughly rinse ice-cube chute, evaporator cover panel, sprayer bank and the corresponding side caps, overflow pipe and
sprayer bank feed pipes under running water
11. refit parts previously removed
12. reposition front panel of appliance and secure with screws
13. reposition top and secure with screws
14. remove right-hand side panel by removing lower screws and extracting it from its seating (Fig. 12)
15. press washing pushbutton (1 in Fig. 12) and refit right-hand side panel by tightening fixing screws
The ice-cube maker can now be reactivated as specified in the instruction book.
IMPORTANT: All the ice produced during the first five cycles after cleaning and sanitizing operations must be
discarded.
When the appliance is cleaned and sanitized, its bin must also be cleaned and sanitized.
THE FOLLOWING ADDITIONAL OPERATIONS ARE REQUIRED FOR SOME PARTICULAR MODELS:
12 MODEL WITH DAILY PRODUCTION OF 750 kg
To access the washing pushbutton (1), remove the front right-hand panel located above the condenser (Fig. 16).
To access the evaporators, remove the front left-hand and rear left-hand panels by unscrewing the fixing screws and lifting them to
release them; then remove the left-hand part of the top by lifting it from the framework of the appliance (Fig. 17).
Repeat the operations described in chapters 10 and 11 on the front and rear evaporators.
At the end of the cleaning and sanitizing operations on the appliance, reposition the panels previously removed, and tighten the
fixing screws.

10 PERIODS AT A STANDSTILL

If you do not intend to use the appliance for a certain period of time, proceed as follows:
• switch off the electric power source by means of the switch (6 in Fig. 4), and remove the plug of the appliance from its socket (if
any)
• shut off the water supply by turning off the water supply tap(s) (7 in Fig. 4)
• carry out all the operations envisaged for scheduled maintenance of the appliance (see chapter 9)
• empty inner basin by removing overflow pipe
• clean filter of water supply solenoid valve as described in chapter 9.1
• clean filter of air condenser (if any) as described in chapter 9.3
E
N
E
N

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Efm500

Inhaltsverzeichnis