5.4 CONNECTION TO THE ELECTRICITY MAINS

IMPORTANT:
• models with daily production of 400 kg and 750 kg must be connected to a 32A interlocked receptacle
• models with daily production of 200 kg must be connected to a 20A interlocked receptacle
• the appliance must be connected to the electricity mains by professionally qualified personnel in accordance with the
Manufacturer's instructions
• before connecting the appliance to the electricity mains, make sure that the mains voltage rating corresponds to the value
indicated on the rating plate
• make sure that the appliance is connected to an efficient earthing system
• make sure that the capacity of the power supply system suits the maximum power value indicated on the rating plate of the
appliance
• if the appliance comes supplied with a plug, prepare a socket controlled by an omnipolar circuit-breaker (6 in Fig. 4), with a
contact-opening gap of not less than 3 mm, that provides full disconnection under overvoltage category III conditions, in
accordance with national safety standards currently in force. This switch must be equipped with fuses, with the associated
residual current device positioned in such a way as to be readily accessible. Insert the plug into the socket controlled by the
switch
• the plug must only be replaced by professionally qualified and authorized personnel, and the new plug must comply with
current national safety standards
• if the appliance comes supplied without a plug and you wish to connect it permanently to the power supply, prepare an
omnipolar circuit-breaker, with a contact-opening gap of not less than 3 mm, that provides full disconnection under overvoltage
category III conditions, in accordance with national safety standards currently in force. This switch must be equipped with
fuses, with the associated residual current device positioned in such a way as to be readily accessible. This operation must
be carried out by a specialized technician
• make sure that you fully uncoil the power supply cable and check that it is not crushed in any way
• should the supply cable be damaged, it must be replaced by a specialized technician using a special cable available from the
Manufacturer or from the Technical Service Centres

5.5 CONNECTING THERMOSTAT TO BIN

The appliance is fitted with a thermostat, the probe of which must be connected to the bin if the appliance is installed on a bin
manufactured by us.
NOTE FOR INSTALLER (Fig. 6):
This operation must only be performed by professionally qualified and authorized personnel.
To access thermostat probe:
• remove right-hand side panel
• release and uncoil probe, taking care not to create any constrictions
• insert probe into hole in baseplate marked by a green arrow
• shape end of capillary tube as shown in Fig. 6 before inserting it into bulb-holding tube of bin, taking care not to damage it
For further details, see the diagrams supplied with our bins.

6 START-UP

6.1 CLEANING INTERNAL PARTS

The appliance will have already been cleaned in the factory. However, you are advised to wash the internal parts again before
using the appliance. Make sure that the power supply cable is unplugged before carrying out the above cleaning operation.
See cleaning and sanitizing manual for information regarding cleaning operations.
For cleaning operations in general, use an ordinary detergent for washing dishes or a solution of water and vinegar. Rinse
thoroughly with plenty of cold water and remove any ice that may have been produced during the first 5 cycles after cleaning,
together with any ice present in the bin.
It is advisable to avoid using abrasive detergents or powders, since these might damage the finish.
6.2 START-UP
When you start up the appliance the first time, or when you start it up again after a long period at a standstill, fill the
basin manually with water.
The filling operation is performed by removing the front panel and pouring water directly into the basin (Fig. 7). In the cycles
subsequent to the initial one, the appliance will be filled with water in a fully automatic way.
Once the appliance has been correctly connected to the electricity mains, water mains and water drain system, it can be started
up as follows:
a) turn on the water supply tap(s) (7 in Fig. 4)
E