5.2 POSITIONING

The appliance must be installed in a hygienically clean location; it is advisable to avoid rooms like cellars and store-
rooms, because failure to meet hygiene requirements is likely to lead to the formation and proliferation of bacteria in the
appliance.
The appliance can operate at an ambient temperature of between 10°C and 43°C.
The best performance will be obtained by installing the appliance in a place with an ambient temperature of between
10°C and 35°C and a water temperature of between 3°C and 25°C.
Avoid direct exposure to sunlight and do not install near heat sources.
This appliance:
• must be installed in a place where it can be supervised by skilled personnel
• must not be used outdoors
• must not be installed in damp places or where it is liable to be sprayed with water
• must not be cleaned with jets of water
• must be allowed a clearance of least 20 cm all around
The appliance must be installed on a bin.
For correct installation on our bins, see the diagrams supplied with the bins.
In any event the instructions and advice contained in this manual must be complied with, especially those relating to connection to
the electricity and water supply.
Use a spirit level to ensure that the appliance is standing perfectly level. If necessary, adjust the legs fitted to our bins.
The manufacturer declines all liability for installation on bins made by other manufacturers.
5.3 CONNECTION TO THE WATER MAINS
IMPORTANT:
• the appliance must be connected to the water mains by professionally qualified personnel in accordance with the
Manufacturer's instructions
• this appliance must be only be supplied with cold water for human consumption (drinking water)
• the operating pressure must be between 0.1 and 0.6 MPa
• a tap must be installed between the water mains and each feed pipe of the appliance, so that the water supply may be shut off
if necessary
• where the feed water is particularly hard, you are advised to install a polyvalent cartridge filter. Any solid particles (e.g. sand)
may be eliminated by installing a mechanical filter, which must be periodically inspected and cleaned. These devices must
comply with the standards in force in the Country of use
• never turn the water supply tap(s) off when the appliance is working
• only new hose-sets supplied with the appliance are to be used to connect the appliance to water mains, old hose-sets should
not be reused
• Is forbidden install the machine to De-ionized or Reverse Osmosis Water
5.3.a FILLING WITH WATER (Fig. 5)
Insert the special seals provided (13) in the two threaded ring nuts (12) of the water supply pipe (8) supplied with the appliance.
Without exerting excessive force (otherwise the unions could crack), firmly tighten one of the threaded ring nuts on the outlet of
the solenoid valve located in the rear of the appliance. The other threaded ring nut must be screwed to the water tap (7); this
too must be provided with a thread.
For water-cooled models, connect union (15) to tap (7 W) with a water supply pipe (9), using a hose clip (14) if necessary.
5.3.b DRAIN (Fig. 5)
Secure water drainage pipe (10) in its seating in the back of the appliance and check that:
• the pipe is a hose
• the internal diameter is 22 mm, as required
• the water drain hose is not throttled at any point throughout its length
• the drain hose slopes downwards by at least 15%
In the case of water-cooled models, connect union (16) to a drainage outlet with a water drainage pipe (11), using a hose clip
(14).
It is advisable to drain the water straight into an open drain trap.