Installation instructions, only for experts
13. Mechanical ventilation in a sauna with an
electric heater
Attention should be paid to the ventilation in the sauna room. Due to proper
ventilation, the sauna-goers can enjoy clean and fresh, oxygen-rich air. The air
in the sauna should change six times in one hour. The fresh air pipe should be
located on top of the heater either in the wall or the ceiling, at approximately 500
mm from the heater and the diameter of the pipe should be 50–100 mm. The
exhaust air pipe should be as far away from the heater as possible, yet close
to the floor. The exhaust air pipe should be twice the size of the supply air pipe.
Supply air
Option 2
Supply air
Option 1
WORLD OF WELLNESS
Supply air from option 1 or 2
p. 15/22
EN
Exhaust
air