0x9F - Detailed
Query:
Description and
Start Length
Example of "Re-
mote Ctrl CMD ID"
0x05
Remote Ctrl Data
Values in the 'Remote Ctrl Data' byte:
Cos phi specified value:
Change gradient:
Reserved data must always be 0x00.
Response:
Start Length
180
Device / Op-
tion
0x09 +
0x00
Num-
ber of
invert-
ers
Cos phi specified
Separator
value
0x7F
Device / Op-
tion
variable 0x00
Number
Com-
mand
0x00
0x9F
Inverter number
Remote Ctrl Data
Change gradient
big endian | signed int | resolution: 1 LsB = 0.001 [-] |
Value range -999d to -001d and +001d to +1000d
Value range limitation for Fronius IG Plus and Fronius CL: -
999d to -750d and +750d to +1000d (extended reactive pow-
er specification), -999d to -850d and +850d to +1000d (stan-
dard reactive power specification)
Value range limitation for Fronius Agilo: -999d to --800d and
+800d to +1000d
big endian | unsigned int | resolution: 1 LsB = Delta 0.001 [-]
/ sec |
Value range 1-65535d / Special value: 0xFFFF is defined as
"as fast as possible"
Value range limitation for Fronius IG Plus, Fronius CL: 1-
15000d / Special value: 0xFFFF is defined as "as fast as pos-
sible"
Value range limitation for Fronius Agilo: 1-100d / Special val-
ue: 0xFFFF is defined as "as fast as possible"
Example: Change from -0.950 to +0.950 corresponds to a
Delta of 100. A change gradient of 1000 entails a change
from -0.950 to +0.950 in 0.1 seconds (calculation: Delta/
Change gradient = 100/1000 = 0.1 seconds)
Number
Com-
mand
0x00
0x9F
Remote Ctrl
Separator
CMD ID
0x05
0x7F
Check-
sum
Separator Reserved
0x7F
0x00
Remote Ctrl
Separator
CMD ID
0x05
0x7F

Quicklinks ausblenden: