REMOTE CONTROL
OPERATION PROCEDURE FOR SWING LOUVER ADJUSMEN
1. When the SWING LOUVER switch is pressed, the swing louver starts its
operation. The range of the swinging angle is approximately 70° from the
horizontal position to the downward position. When the "
moving, it indicates conitnous operation of the louver.
2. When the swinging operation of the louver is not required, press the
Swing
SWING LOUVER switch again. The louver is stopped at an angle indicated
louver
by the direction of this mark "
setting
3. Discharge air angle is fi xed (at 20° for RCI series and 40° for RCD series)
during start-up of heating operation and defrosting operation when
thermostat is ON. When the outlet air temperature reaches above 30 °C,
swinging of louvers is started.
1. In the case of cooling and dry operation, discharge air angle can be
changed at 5 positions. In the case of heating operation, it can be changed
at 7 positions
2. To fi x the louver position, fi rst press the SWING LOUVER switch to start
the louver swinging, and then press the SWING LOUVER switch again
when the louver reaches the required position.
3. Discharge air angle is fi xed (at 20° for RCI series and 40° for RCD series)
during start-up of heating operation and defrosting operation when
thermostat is ON. When the outlet air temperature reaches above 30 °C,
swinging of louvers is started.
4. When the louvers are fi xed at an angle 55° RCI, 65° RCD or 70° both
during heating operation and the operation mode is changed to cooling
Fixing of
operation, louvers will be automatically fi xed at an angle of 45° RCI, 60°
Louver
RCD.
NOTE:
There is a time lag between the actual angle of the louver and
-
the liquid crystal indication. When the SWING LOUVER switch
is pressed, the louver will not stop immediately. The louver will
move one extra swing. If the louvers are moved due to cleaning
or for any reason, set Auto Setting mode to place the four
louvers in in the same position.
Do not turn the air louver by hand. If moved, the louver mechanism could be damaged!
(In all units)
Wall Type (RPK):
-
Adjust the vertical defl ectors by hand to discharge air in the required direction.
Do not swing 1 blade at left side and 2 blade at right side of the vertical defl ection.
Automatic Setting of louver
-
When the unit operation is stopped, two air louvers are stopped at closing position
automatically.
Ceiling Type (RPC):
The vertical defl ector consists of four sets of defl ectors. Adjust the vertical defl ectors
by hand to discharge air in the required direction.
NOTE:
For models without automatic swing louver the above indications are not
-
available through R.C.S. The swing Louver should be adjusted by hand
in this case.
Downloaded from
www.Manualslib.com
".
manuals search engine
RCI (4-Way cassete type)
" mark is
Indication
Louver angle
Approx.
Approx.
(aprox.)
20°
Cooling.
Heating
Angle range
Recommended angle
RCD (2-Way cassete type)
Indication
Louver angle
Approx.
Approx.
(aprox.)
40°
Cooling.
Heating
Angle range
Recommended angle
RPK (Wall type)
Indicación
Louver angle
Approx.
Approx.
(aprox.)
35°
Cooling.
Louver angle
Approx.
Approx.
(aprox.)
40°
Heating
Angle range
Recommended angle
RPC (Ceiling type)
Indication
Louver angle
Approx.
Horizontal
(aprox.)
Cooling.
Heating
Angle range
Recommended angle
Vertical defl ector
Horizontal defl ector
One set
Vertical defl ector
PMGB0126A rev.2 - 11/2006
Approx.
Approx.
Aprox.
Approx.
Approx.
25°
30°
35°
45°
55°
70°
Angle range
Angle range
Approx.
Approx.
Approx.
Approx.
Approx.
45°
50°
55°
60°
65°
70°
Angle range
Angle range
Approx.
Approx.
Approx.
Approx.
Approx.
40°
45°
50°
55°
60°
70°
Angle range
Approx.
Approx.
Approx.
Approx.
Approx.
45°
50°
55°
60°
65°
70°
Angle range
Approx.
Approx.
Approx.
Approx.
Approx.
15°
30°
40°
50°
60°
80°
Angle range
Angle range
CAUTION: