OPERATION

Appliance description

WARNING Injury
!
The appliance may be used by children aged 3 and older
and persons with reduced physical, sensory or mental
capabilities or a lack of experience and know-how, pro-
vided that they are supervised or they have been in-
structed on how to use the appliance safely and have
understood the potential risks. Children must never play
with the appliance. Children must never clean the ap-
pliance or perform user maintenance unless they are
supervised.
Where children or persons with limited physical, sensory or men-
tal abilities are allowed to use this appliance, we recommend a
permanent temperature limit. The following limitation options
are available:
- User adjustable: Temperature limit (e.g. for childproofing)
- Qualified contractor adjustable: Internal anti-scalding
protection.
Material losses
!
The user should protect the appliance and its tap against
frost.
2.3

Test symbols

See type plate on the appliance.
2.4

EU Declaration of Conformity

Note
DHB-E LCD: STIEBEL ELTRON hereby declares that the
radio equipment type complies with Directive 2014/53/
EU. The full text of the EU Declaration of Conform-
ity can be found at the following internet address:
www.stiebel-eltron.de/downloads
3.
Appliance description
The appliance switches on automatically as soon as you open the
hot water valve on the tap. When you close the tap, the appliance
switches off again automatically.
The appliance heats water as it flows through it. The DHW outlet
temperature can be variably adjusted. From a certain flow rate,
the control unit regulates the correct heating output, subject to
the temperature selected and the current cold water temperature.
The electronically controlled instantaneous water heater with au-
tomatic output matching maintains a consistent outlet tempera-
ture. It is irrespective of the inlet temperature, up to the maximum
output of the appliance.
If the appliance is operated with preheated water and the inlet
temperature exceeds the chosen set temperature, the water will
not be heated further.
You can set the temperature unit (°C or °F) according to prefer-
ence.
28
| DHB-E LCD
Heating system
The bare wire heating system is enclosed within a pressure-tested
plastic jacket. The heating system with its stainless steel internal
indirect coil is suitable for hard and soft water areas and is largely
insusceptible to scale build-up. The heating system ensures rapid
and efficient DHW provision.
Note
The appliance is equipped with an air detector that large-
ly prevents damage to the heating system. If, during op-
eration, air is drawn into the appliance, the appliance
shuts down for one minute, thereby protecting the heat-
ing system.
4.

Settings and displays

4.1

Setting the temperature

2
1
1 Temperature selector for adjusting set temperature (no end-
stop): "OFF", 20 - 60 °C (factory setting)
2 Display
3 Temperature unit [°C/°F]
Temperature settings in steps
Temperature range
Step
20 °C ... 60 °C
1 °C
Selecting the temperature indicator
You can choose to display the temperature in °C or °F, as required.
f Turn the temperature selector anti-clockwise, past the OFF
f
indicator and another five complete turns, until you find
yourself in temperature unit selection mode. Then select the
temperature unit using the temperature selector. After 30 s,
the appliance exits selection mode automatically and the se-
lected temperature unit is retained.
Note
If the outlet temperature is not high enough when the
draw-off valve is fully open and the temperature selector
is set to maximum, then more water is flowing through
the appliance than can be heated by the heating system
(appliance working at maximum output).
f Reduce the water volume until the preferred tem-
f
perature delivery is achieved.
3
Temperature range
Step
68 °F ... 140 °F
1 °F
www.stiebel-eltron.com