INSTALLATION
Installation
Installing the appliance
Note
If you are installing the appliance with flexible pipe con-
nections, also secure the back panel with a screw.
1 Cable entry installation aid
2 Cable grommet
Use the installation aid for easier wiring access through the cable
grommet (see plastic parts set supplied).
f Remove the cable grommet from the back panel.
f
f Pull the cable grommet over the cable sheath of the power
f
cable. For large cable cross-sections, enlarge the hole in the
cable grommet if necessary.
f Remove the transport protection plugs from the appliance
f
pipe connections.
f Bend the power cable 45° upwards.
f
f Route the power cable and cable grommet through the back
f
panel from the rear.
f Install the appliance on the threaded studs of the wall
f
mounting bracket.
f Press the back panel firmly into place, aligning it correctly.
f
f Lock the fixing toggle by turning it 90° clockwise.
f
f Pull the cable grommets into the back panel, until both lock-
f
ing tabs engage.
34
| DHB-E LCD
1
2
19
3 Nm
f Fit the pipe connections with flat gaskets onto the water
f
connections.
f Open the 3-way ball shut-off valve or the shut-off valve in the
f
cold water supply line.
Making the electrical connection
WARNING Electrocution
Carry out all electrical connection and installation work
in accordance with relevant regulations.
WARNING Electrocution
The connection to the power supply must be in the form
of a permanent connection in conjunction with the re-
movable cable grommet. Ensure the appliance can be
separated from the power supply by an isolator that dis-
connects all poles with at least 3 mm contact separation.
WARNING Electrocution
Ensure that the appliance is earthed.
Material losses
!
Observe the type plate. The specified rated voltage must
match the mains voltage.
f Connect the power cable to the mains terminal.
f
Fitting the lower back panel section
1
1 Diffuser on lower back panel
f Fit the lower back panel section into the back panel. Check
f
that both locking tabs are engaged.
f Align the mounted appliance by undoing the fixing toggle,
f
aligning the power supply and back panel, and then re-tight-
ening the fixing toggle. If the back panel does not sit flush
against the wall, you can secure the appliance at the bottom
with an additional screw.
Material losses
!
Do not bend the diffuser on the lower back panel when
installing.
24
5 Nm
www.stiebel-eltron.com