AVOID ANY PHYSICAL DAMAGE
Before carrying out maintenance on the
machine:
1. Put the machine in a stable configuration
with the horizontal axis completely retracted
and the pole in working or resting position
(Fig. 12c).
12a
8.1. PRELIMINARY CHECKS
Check that there is a pressure of at least 8 bar on the filter regulator pressure gauge.
If the pressure is below the minimum level, some machine operations may be limited
or insufficient.
After the correct pressure has been restored, the machine will operate properly.
Check that the machine has been adequately connected to the electric mains and the
pneumatic supply.
8.2. DECIDING FROM WHICH SIDE OF THE WHEEL THE TYRE
MUST BE REMOVED
See Fig.13. Identify the position of channel A on the
rims. Identify the greater width B and the smaller width
C. The tyre must be mounted and demounted with
the wheel on the turntable with the smallest width
side C facing upwards.
A 2030 - A 2025 - A 2022 - A 2018 - A 224 A - A 224 Operator's manual
CAUTION
2. Disconnect the power supply
plug (Fig 12a).
3. Isolate the compressed air line
by disconnecting the closing valve
(quick release connector) (Fig. 12b.)
12b
12c
C
A
EN
B
13
103