Herunterladen Diese Seite drucken

Connecting A Divar - Bosch DVA-08E Schnellstartanleitung

Raid subsystem
Vorschau ausblenden Andere Handbücher für DVA-08E:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36
92
en | Connecting a Digital Video Recorder
12.2
F.01U.027.800 | V5 | 2010.06
Downloaded from
www.Manualslib.com

Connecting a Divar

The following hardware is required to connect a Divar:
To connect a Divar with the first subsystem you need the DVA-ACON-HD50A SCSI cable.
To expand an existing system (Divar and subsystem) with an additional subsystem, you
must order the DVA-ACON-VD680A (0.5 m/20 in.) SCSI cable.
To connect the Divar:
1.
Connect the Divar with the subsystem. You must switch the Divar and the subsystem off.
Take care of proper connection and tighten the screws of the plug.
NOTICE!
Two subsystems: Make the SCSI connection after you have changed the SCSI ID of the
second subsystem.
Due to SCSI specifications, do not daisy chain more than two subsystems.
The DVA-08E does not support daisy chaining.
Do not assign drives bigger than 2 TB to Divar. In the factory default settings all disk
arrays are configured with logical drives (LD) smaller than 2TB.
You may assign SCSI IDs from 0 to 6. If you use the internal DVD writer option, the SCSI
ID 5 is reserved for the DVD drive. Always use LUN 0 otherwise Divar will not discover the
drive.
CAUTION!
The internal disks of Divar must be disabled when using a disk array in Raid 5 mode.
Otherwise if an internal disk fails, all data is lost (even on the subsystem).
Figure 12.2 Connecting Divar
1
Divar
2
RAID subsystem (no daisy chaining
for DVA-08E)
3
Divar SCSI port
4
CH0-IN
2.
For daisy chaining several subsystems, you must switch off the SCSI channel's
termination of the used SCSI channel of all subsystems except the last.
Expand the configuration tree -> click Configuration -> Channel -> Channel 0 or
Channel 1 -> ID Tab -> Termination: Disabled -> Apply.
3.
Click Configuration -> Configuration Parameters -> System tab -> Reset the Controller -
> Apply. The subsystem is reset.
4.
For daisy chaining, change the SCSI channel IDs of the second subsystem.
Expand the configuration tree -> click Configuration -> Channel -> Channel 0 or
Channel 1 -> Parameters Tab -> for DVA-08K: clear the 0 and 1 check boxes and select
the 2 and 3 check boxes -> Apply.
manuals search engine
5
6
7
Quick Installation Guide
RAID Subsystem DVA-08E, -08K, -16K
CH0-OUT
DVA-ACON-HD50A SCSI cable
DVA-ACON-VD680A SCSI cable
Bosch Sicherheitssysteme GmbH

Werbung

loading

Diese Anleitung auch für:

Dva-08kDva-16k