3.2.4. Setpoints
The height- and angle instruments can display two separate user-configured reference positions, called setpoints. The setpoints
are a visual aid for controlling the loader to a specific position. You can also choose to set a set-point together with a sound
notification, in which case the display will beep when a set-point is reached.
You can set or clear the setpoints by pressing Configure setpoints, select the setpoint you would like to configure and then Set,
Set with beep or Clear.
magnus
0
43
bucket / gravel
When pressing Set or Set with beep, the current loader- or implement position is used as set-point.
3.3. Diagnostics
The diagnostic view is found from the Settings view. In the diagnostic view, some basic information about the system and its
usage is presented.
Settings
User settings
Diagnostics
Maintenance
Loader setup
Display settings
Factory reset
-
Lifting time: The number of hours the loader
arm has been moving.
-
Dump time: The number of hours the tool
carrier has been moving. For a parallel loader,
the tool carrier will always move when the
loader arm is moving, even if no tilt movement
is commanded by you.
Oper time: The number of hours the system has
-
been powered on.
Load cycles: The number of performed lifts.
-
-
Loader type: The loader type as configured
during product setup wizard.
14:56
Setpoints
Implement crowded
Implement dumped
Loader high
Loader low
26
Fig.49 Setpoints
Fig.50 Diagnostics
Diagnostics
Lifting time _ _ _ hrs
Dump time
_ _ _ hrs
Oper. time
_ _ _ hrs
Load cycles _ _ _
Loader type: Self levelling
33
Operation
Implement crowded
Set
Set with beep
Clear