Herunterladen Diese Seite drucken

Preparation For Operation - PeakTech 2005 A Bedienungsanleitung

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7. 10 A - Input Terminal
For current measurements (AC or DC) up to 10A when the
rotary selector switch is in the 10A position.
8. mA Input terminal
For current measurements up to 200mA DC/AC when the
rotary selector is in the mA position.
9. COM Common Terminal
Return terminal for all measurements.
10. V//Hz – Input Terminal
Continuity, Diode, Ohms, Volt, Frequency terminal.

5. Preparation for Operation

5.1. Using the test leads
Use only the identical type of test leads supplied with your
meter. These test leads are rated for 1000V.
Cautions!
*
The maximum rating of your meter is 1000V DC and
AC. If you try to measure voltages above 1000V DC or
AC, you might damage your meter and expose yourself
to a serious shock hazard. Use extreme care when you
measure high voltages.
*
Never connect the probe you plug into the COM terminal
to a source of voltage greater than 1000V DC/AC with
respect to earth/ground. This creates a serious shock
hazard.
46

Werbung

loading