Operation in Master-Slave mode:
To set a fixture to slave-mode navigate to REMOTE. To activate the slave function press "ENTER"
(keep it down) and press "ESC" in addition. The display will show either REMOTE INACTIVE if
no DMX-signal is being received or REMOTE ACTIVE if a DMX-signal is being received. To leave
this function press "ESC" (keep it down) and press "ENTER" in addition. Connect the P7 with
DMX cables. Select STANDALONE -> RUN with the master fixture. Start function by pressing
"ENTER" (keep it down) and pressing "ESC" in addition. All connected fixtures will repeat the
steps synchronized to the master fixture. To leave the menu press "ESC" (keep it down) and press
"ENTER" in addition. If you realize that a fixture reacts inaccurate check if the display shows
REMOTE ACTIVE.

5.7 INFO

The menu informs about the current software/firmware version. The non-resettable TOT OPER-
ATE TIME counter displays total hours of use since the P7 was manufactured.
Temperature readouts from the P7 base (TEMP BASE) as well as the driver (TEMP HEAD DRV)
and the LED module (TEMP HEAD LED) in the head are available. In each case, you can view
the current temperature and the maximum temperature reached since the readout was last reset
individually.