9.4.2 Cleaning device
The "Cleaning 1..." and "Cleaning 2..." menus are used for the
DID with sensor for tank immersion, if an automatic cleaning
device is installed.
Cleaning 1...
Interval [s]:
Duration [s] :
Wait [s]
:
Clean now!
Interval [s]:
The time between two cleaning actions
Duration [s] :
The time the cleaning device is activated for one
cleaning action
Wait [s]
:
The time before starting a new measurement
after a cleaning action is finished
Clean now!
Automatic cleaning test
Changing the cleaning interval
1. Select "Interval [s]:
" with the [Up] and [Down] buttons.
Confirm with [OK].
2. Change the interval value with the [Up] and [Down] buttons.
Confirm with [OK].
Changing the cleaning duration
1. Select "Duration [s] :
" with the [Up] and [Down] buttons.
Confirm with [OK].
2. Change the duration value with the [Up] and [Down] buttons.
Confirm with [OK].
Changing the delay before a new measurement
1. Select "Wait [s]
: " with the [Up] and [Down] buttons.
Confirm with [OK].
2. Change the delay value with the [Up] and [Down] buttons.
Confirm with [OK].
Testing automatic cleaning
1. Select "Clean now!" with the [Up] and [Down] buttons. Confirm
with [OK].
9.4.3 Measurement settings
Meas. settings
Interval [s]:
Average:
Log. Interval:
Use Fahrenheit:
Ignore limits:
Time between two measurements in a range of
Interval [s]:
1-3600 seconds.
The displayed value is averaged over the last x
Average:
readings. "Average:
and 10.
Each x reading is stored in the logged result file.
Log. Interval:
"Log. Interval: " can be set between 1 and 60.
Temperature values are displayed in [°C] by
Use Fahrenheit:
default. If set to "Yes", all temperature values
are displayed in [F].
If set to "Yes", also parameter values outside the
Ignore limits:
nominal measuring range can be used to
configure outputs, alarm limits, etc.
Changing the measurement interval
1. Select "Interval [s]:
" with the [Up] and [Down] buttons.
Confirm with [OK].
2. Change the interval value with the [Up] and [Down] buttons.
Confirm with [OK].
– This changes also the sampling interval of the analog and
digital inputs.
16
9.4.4 Date/Time
120
2
10
Changing the year
1. Select "Year :
2. Change the year value with the [Up] and [Down] buttons.
Changing the month
1. Select "Month :
2. Change the month value with the [Up] and [Down] buttons.
Changing the day
1. Select "Day :
2. Change the day value with the [Up] and [Down] buttons.
Changing the hour
1. Select "Hour :
2. Change the hour value with the [Up] and [Down] buttons.
Changing the minute
1. Select "Minute:
2. Change the minute value with the [Up] and [Down] buttons.
5
4
45
No
No
" can be set between 1
Date/Time
Year :
Month :
Day :
Hour :
Minute:
" with the [Up] and [Down] buttons.
Confirm with [OK].
Confirm the new year with [OK].
" with the [Up] and [Down] buttons.
Confirm with [OK].
Confirm the new month with [OK].
" with the [Up] and [Down] buttons.
Confirm with [OK].
Confirm the new day with [OK].
" with the [Up] and [Down] buttons.
Confirm with [OK].
Confirm the new hour with [OK].
" with the [Up] and [Down] buttons.
Confirm with [OK].
Confirm the new minute with [OK].
2020
Jan
8
6
43