Note is valid for Turkey only: The lifetime of our products is ten (10) years
Service Parts
Indoor air filter
Indoor unit
Indoor Fan
Do not operate any heating apparatus too close to the air conditioner unit. This may cause the plastic panel to melt or
For any enquiries on spare parts, please contact your authorized dealer. When any malfunction of the air conditioner
unit is noted, immediately switch off the power supply to the unit. Check the following fault conditions and causes for
some simple troubleshooting tips.
1.
The compressor does not operate 3 minutes after the
air conditioner unit is started.
2.
The air conditioner unit does not operate.
3.
The airflow is too low.
4.
Discharge airflow has bad odor.
5.
Condensation on the front air grille of the indoor
unit.
6.
Water flowing out from the air conditioner unit.
If the fault persists, please call your local dealer / serviceman.

SERVICE AND MAINTENANCE

Maintenance Procedures
1.
Remove any dust adhering to the filter by using a vacuum cleaner
or wash in lukewarm water (below 40°C) with a neutral cleaning
detergent.
2.
Rinse the filter well and dry before placing it back onto the unit.
3.
Do not use gasoline, volatile substances or chemicals to clean the
filter.
1.
Clean any dirt or dust on the grille or panel by wiping it with a soft
cloth soaked in lukewarm water (below 40°C) and a neutral detergent
solution.
2.
Do not use gasoline, volatile substances or chemicals to clean the
indoor unit.
1.
Check for any abnormal noise.
deform as a result of the excessive heat.

TROUBLESHOOTING

Fault
! CAUTION
Protection against frequent starting. Wait for 3 to 4
minutes for the compressor to start operating.
Power failure, or the fuse needs to be replaced.
The power plug is disconnected.
It is possible that your delay timer has been set
incorrectly.
The air filter is dirty.
The air suction and discharge are clogged.
The regulated temperature is not high enough.
(applicable for auto-fan mode only)
Odors may be caused by cigarettes, smoke particles,
perfume etc. Which might have adhered onto the coil.
This is caused by air humidity after an extended long
period of operation.
The set temperature is too low, increase the temperature
setting and operate the unit at high fan speed.
Switch off unit and call local dealer / serviceman.
1-20
Period
At least once every
2 weeks.
More frequently if
necessary.
At least once every
2 weeks.
More frequently if
necessary.
When necessary.
Causes / Action