Operating Instructions
QJ 600-E
7.3
Suction plates / seals
Remove any foreign bodies and contamination such as adhesives, glue, sawdust, dust, etc. sticking to the
seals at least once a week. Use glycerine to clean the seals.
Immediately replace damaged seals (tears, holes, waves).
Do not use petrol (gasoline).
Use cleaning agent to clean the device (do not use petrol (gasoline) or aggressive or corrosive fluids to
clean the device. The hoses will otherwise become leaky or be destroyed).
Suction plates must always be replaced completely. The bolts of the suction plate can be loosened more
easily by heating.
7.4
Leak Test
Check the device for leaks at least every three months.
●
Apply the suction pad to a flat air-tight surface.
●
Switch the vacuum blower on and wait until a vacuum of at least -200 mbar
is reached.
If this vacuum level is not reached, check:
●
whether the seals or hoses are damaged,
●
that the connectors are tight,
●
that the filter element is clean.
7.5 Repairs
●
Only persons with the appropriate knowledge and ability are allowed to repair the device.
●
Before the device is used again, it has to be checked by an expert.
7.6 Safety procedures
It is the contructors responsibility to ensure that the device is checked by an expert in periods of
max. 1 year and all recognized errors are removed ( see BGR 500).
The corresponding legal regulations and the regulations of the declaration of conformity have to be
observed!
We recommend, that after checking the device the badge „Safety checked" is put on the device.
(Order-No.: 2904.0056+inspection sticker with date).
●
You can receive these badges from us.