3.6 Interface connections

The serial interface can perform the following functions:
- retrieve data,
- program and retrieve parameters.
Interface parameters are:
- transmission speed (Baud rate),
- parity bit,
- number of stop bits,
- address by which the master approaches the control instrument.
The interface parameters can be set in the programming mode.
RS232 Full-duplex transmission with the following features:
- asymmetric
- 3 lines
- point-to-point connection - 1 emitter and 1 receiver
- distance of data transfer: max. 30 m
RS422 Full-duplex transmission with the following features:
- symmetric
- 4 lines
- point-to-point connection - emitter and receiver (max. 32 units)
- distance of data transfer: max. 1500 m
RS485 Half-duplex transmission with the following features:
- symmetric
- 2 lines
- multi-point connection - emitter and receiver (max. 32 units)
- distance of data transfer: max. 1500 m
➜ Assign terminals 14 and 15 and where applicable 16 to 19 to the
corresponding interface.

3.7 Executing test routine

The test routine is described below.
device (hold down the above keys at the same time).
● All the display segments will be displayed automatically in se-
quence and are thereby tested for functional capability.
interface in sequence.
No machine functions may be connected when the outputs are
tested.
Keyboard test
Input test
● Inputs can be controlled simultaneously or individually. A display
is only provided when a signal is applied.
www.baumer.com
and
simultaneously then switch on the
key, test the keyboard, the inputs, outputs and