BE134
Sensor
Contact
Proximity switch PNP or NPN
Namur without explosion protection
26
3.5 Example of connection
3.6 Sensor supply connection
Connect the sensor supply at terminals 12 and 13 – for example en-
coder supply, etc.
Do not use the sensor supply to supply non-earthed inductive or
capacitive loads. The sensor supply is short-circuit proof (exception
model 24/48 VAC).
Voltage supply
24 VAC
48 VAC
85...265 VAC
12...30 VDC
3.7 Interface connection (Option)
The serial interface can perform the following functions:
- retrieve data
- program parameters
Interface parameters are:
- transmission speed (baud rate),
- parity bit,
- number of stop bits,
- address of controller for master.
The interface parameters can be set on the programming level (Lines
51, 52, 53 and 54).
www.baumer.com
Contact assignment Programming
7/8
Start/Stop
12
+24 V
7/8
Start/Stop
12
+24 V
13
0 V
7/8
Start/Stop
13
0 V
Sensor supply
10...26 VDC
10...26 VDC
24 VDC ±20 %
9...28 VDC ±20 %
Function of signal
inputs:
line 30 to 0, 1 or 2
Input logic:
Line 33 to 0 = PNP
Line 33 to 1 = NPN
Input logic:
Line 33 to 1 = NPN
Current load
60 mA
60 mA
100 mA
100 mA