Sensor
Contact
Proximity switch PNP or NPN
Namur without ex. protection
Incremental encoder
30
3.5
Examples of connection
Contact assignment Programming
3.6

Sensor supply connection

Connect the sensor supply at terminals 12 and 13 – for example en-
coder supply, etc.
Do not use the sensor supply to supply non-earthed inductive or
capacitive loads. The sensor supply is short-circuit proof (exception
model 24/48 VAC).
Voltage supply
24 VAC
48 VAC
85...265 VAC
12...30 VDC
3.7

RS485 interface connection

The serial interface can perform the following functions:
- retrieve data
- program parameters
Interface parameters are:
- transmission speed (baud rate),
- parity bit,
- number of stop bits,
- address of controller for master.
www.baumer.com
Counting rate:
7
Track A
Line 31 to 1 = 25 Hz
12
+24 V
Line 31 to 2 = 3 Hz
7
Track A
Input logic:
12
+24 V
Line 33 to 0 = PNP
13
0 V
Line 33 to 1 = NPN
7
Track A
Input logic:
13
0 V
Line 33 to 1 = NPN
Counting mode
7
Track A
A 90° B (x1, x2, x4)
8
Track B
Line 30 to 3, 4, 5
12
+24 V
Count frequenz:
13
0 V
Line 31, 32 to 0 = 10 kHz
Sensor supply
10...26 VDC
10...26 VDC
24 VDC ±20 %
9...28 VDC ±20 %
Current load
60 mA
60 mA
100 mA
100 mA

Werbung