10 Troubleshooting

DANGER
Risk of injury and device damage when handled by unauthorised persons
Improper repair work and modifications to the product may lead to serious injuries and damage to the device. The
product warranty will be rendered invalid if work is carried out on the product by unauthorised persons.
• Only qualified personnel are permitted to perform work on the device or system.
CAUTION
• Suitable safety measures must be taken before performing maintenance and cleaning work.
• Maintenance and cleaning work must only be carried out on the extraction system in areas with locally filtered forced
ventilation.
• Always wear your personal protective equipment when performing maintenance and cleaning work.
• Personal protective equipment consists of protective clothing, safety goggles, a class P3 respiratory mask, protective
gloves and safety shoes.
Please observe the attached 'Warranty' document. In the event of any doubts and/or problems, please contact your retailer
or ABICOR BINZEL.
NOTICE
• Consult the documentation for the welding components.
Fault
Extraction volume too low.
External extraction system does
not start.
Dust escapes from the dust collecting
drawer.
Filter cleaning does not work.
Tab. 6
Troubleshooting
BAL.0731.0 • 2020-07-14
Cause
• Filter elements saturated.
• Dust collecting drawer not properly
sealed.
• Extraction hose blocked.
• Extraction hose defective.
• Power supply defective.
• Electrical components defective.
• Carbon brushes defective
• Dust collecting drawer not properly
sealed.
• Dust collecting drawer full.
• Compressed air supply faulty.
10 Troubleshooting
Troubleshooting
• Replace the filter elements.
 9.4 Replacing the filter
cartridges on page EN- 15
• Check and install correctly.
 9.5 Emptying the dust
collecting drawer on page EN-
16
• Clean the extraction hose.
• Replace the extraction hose.
 6.2 Attaching the welding
torch's extraction hose on
page EN- 10
• Check and replace if necessary.
• Check and install correctly.
 9.5 Emptying the dust
collecting drawer on page EN-
16
• Empty the dust collecting drawer.
 9.5 Emptying the dust
collecting drawer on page EN-
16
• Check and replace if necessary.
EN - 17