Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Carbon Brushes En; Replacing The Filter Cartridges En - Abicor Binzel xFUME ADVANCED Betriebsanleitung

Vorschau ausblenden Andere Handbücher für xFUME ADVANCED:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

xFUME ADVANCED
9.3 Replacing the carbon brushes
The first set of carbon brushes has a service life of approx. 800 hours with 230 V and of approximately 500 hours
with 115 V. The service life is reduced by 20% each time a carbon brush is replaced. The carbon brushes can be replaced
twice in total. After two replacements, the motor must then be replaced.
1)
Fig. 7
Replacing the carbon brushes
 Step 1 to step 5 on page EN-14
1 Loosen the clamps on the sides and remove the turbine cover.
2 Remove the carbon brush cover and replace the carbon brushes.
3 Dispose of the brushes in accordance with local regulations (no Fig.).
 12 Disposal on page EN- 19
4 Reverse the steps above to reassemble the system (no Fig.).
9.4 Replacing the filter cartridges
3)
Fig. 8
Replacing the filter cartridges
1 Use the device On/Off switch (4) to switch off the welding fume extraction system. (Fig. 5).
2 Pull out the mains plug (no Fig.).
3 Loosen the lower clamps and remove the housing.
4 Unscrew the filter cartridges and replace with new ones.
5 Dispose of the dust collecting bag in accordance with local regulations (no Fig.).
 12 Disposal on page EN- 19
6 Reverse the steps above to reassemble the system (no Fig.).
BAL.0731.0 • 2020-07-14
9 Maintenance and cleaning
2)
4)
EN - 15

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis