Menu no.
Parameter /
info
MP running
4.13
time
CP running
4.14
time
Total cycles
4.17
of panel
MP switch
4.18
cycles
CP switch
4.19
cycles
Switchgear
4.22
serial num-
ber
Software
4.24
version
Menu no.
Parameter /
info
Installation
5.00
Pump type
5.04
Number of
5.05
CP
Sensor
5.11
range pres-
sure
Sensor
5.21
range level
cistern
Level sensor
5.22
installation
height
High water
5.24
on threshold
cistern
Cistern
5.26
shape
Cistern high/
diameter
5.29
Pump kick
5.40
Pump kick
5.42
interval
PUmp kick
5.43
duration
34
Description
Min.
Max. Text
0
6553
5
0
6553
5
0
6553
5
0
6553
5
0
6553
5
0
9999
9999
9
0
9999
Parameters such as the rainwater storage tank dimensions have to be set in this
menu
Min.
Max. Text
HiMulti3-24; HiM-
ulti3-25; HiM-
ulti3-45
0
1
0.0
16.0
0.0
25.0
1
1000
1
1000
none; rectangle -
cylindric; cylindric
horizontal - sphere
1
1000
1
336
1
60
Default
Unit
Ac-
cess
level
0
h:mi
1
n
0
h:mi
1
n
0
1
0
1
0
1
0
1
V5.000
1
Default
Unit
Ac-
cess
level
1
HiMulti3-24
3
0
2
10.0
bar
3
5.00
m
3
15
cm
3
<5.51>+5
cm
3
rectangle
2
110
cm
3
On
2
24
h
2
5
s
2
Description
Operating time of MP
Operating time of CP
The number of power-on cycles for the
panel
The number of power-on cycles for MP
The number of power-on cycles for CP
ID of the panel
The software version of the installed ap-
plication
Description
The settings regarding the installation of
the panel in a system
Select of pump type to define pump
curves to get optimized set pressure for
switch-off refer in menu 1.05
Contains the number of pumps dedicated
to a cistern
Defines the range of the installed analog
pressure sensor
Defines the range of the installed analog
pressure sensor
Distance between ground level and in-
stalled height of sensor
The level threshold in cistern above high
water is reported (distance refer to 5.51)
5.22 < 5.51 < 5.24 < 5.29
If cistern has a defined shape it can be
selected here and can be used to calcu-
late volume capacity of the water
If a shape cylindric horizontal or sphere
for cistern is selected that is required a
diameter it is defined here for calculate
volume capacity 5.22 < 5.51 < 5.24 <
5.29
Enable or disable pump kick functionality
The interval between pump kicks or after
pumps have stopped until the next pump
kick
The time which pump is running during
pump kick