34 | MS 80 | First start up
4.3

Pneumatic connection

1. Connect the MS 80 to the compressed air supply
unit.
2. Adjust to a pressure between 8 and 12 bar.
« Pull the red knurled screw (pressure reducing val-
ve) fi rst upwards and then twist it to adjust ope-
rating pressure.
« Check pressure on the manometer.
|
1 695 301 988
2011-04-04
4.4

Electrical connection

1. Check the correspondence of the mains tension and
the tension shown on the identification tag.
2. Ask a qualified electrician to mount a connection
plug for single-phase or (depending on the tension
you have ordered ) three-phase current (see the
electrical connections diagram inside the electrical
panel).
i
The costs of arranging a mains protection device for
the plug are borne by the customer.
3. Protect the MS 80 according to specific national
rules.
4.5

Check rotation direction

Warning - malfunctioning danger!
The MS 80 rotates counter-clockwise.
Turn off the main switch.
Check the part dedicated to functioning
anomalies to find the cause (see chap. 5.6)
For a correct functioning of MS 80 it is extremely im-
portant that after having connected and started the ma-
chine the rotation direction corresponds to that shown
by the arrow on the control unit motor.
Fig. 2:
Check rotation direction.
Beissbarth GmbH