Operating Manual SATAjet 1500 B RP/HVLP
Adjusting the material flow rate
Information!
There will be less wear on the paint nozzle and paint needle if the ma-
terial flow control is fully open. Select the nozzle size depending on the
spray medium and working speed.
The quantity of material and thus the needle lift can be variably adjusted
using the adjustment screw as shown in figures [4-1], [4-2], [4-3] and
[4-4].
■ Loosen counter nut [1-4].
■ Pull trigger [1-11] all the way off.
■ Adjust material flow rate using adjustment screw [1-3].
■ Tighten counter nut by hand.
Adjustment of the Spray Fan Pattern
The spray jet can be variably adjusted using round/flat fan control [1-2]
until a round fan pattern is produced.
■ The fan pattern can be set by turning the round/flat fan control [1-2].
■ Turn right [5-2] – round fan pattern
■ Turn left [5-1] – flat fan pattern
Starting to paint
■ Maintain spray distance (see Chapter 7).
■ Squeeze trigger all the way [6-2] and operate paint spray gun 90° to
the surface to be painted [6-1].
■ Provide for spray air supply and material supply.
■ Pull back on trigger [1-11] and start painting. Readjust the material flow
rate and fan pattern as needed.
Completing the painting operation
■ Move the trigger [1-11] to the start position.
■ When you are finished painting, stop the spray air and empty the gravity
flow cup [1-16]. Read and follow the information on care and storage
(see 10).