Operating Manual SATAjet 1500 B RP/HVLP
(address see chapter 16).
Malfunction
Jerky spray fan pat-
tern (wobbling / splut-
tering) or air bubbles
in the gravity flow cup.
Air bubbles in gravity
flow cup.
Spray pattern too
small, slanted,
one-sided or split.
Round / flat fan control
not working – control
can be regulated.
Cause
Fluid tip not tightened. Tighten fluid tip with
Air distribution ring
damaged or clogged.
Loose air cap.
Gap between air cap
and fluid tip (air circuit)
is clogged.
Nozzle set is soiled.
Damaged nozzle set.
Not enough material in
gravity flow cup.
Defective paint needle
seal.
Air cap holes clogged
with paint.
Damaged fluid tip
(fluid tip aperture).
Air distribution ring not
correctly positioned
(pin not in hole) or
damaged.
Corrective action
universal spanner.
Replace air distribution
ring (see chapter 9.2).
Tighten the air cap
hand-tight.
Clean air circuit. Heed
cleaning instructions
(see chapter 10).
Clean nozzle set. Heed
cleaning instructions
(see chapter 10).
Replace nozzle set (see
chapter 9.1).
Fill gravity flow cup (see
chapter 8.2).
Replace paint needle
seal (see chapter 9.3).
Clean air cap. Heed
cleaning instructions
(see chapter 10).
Check fluid tip for dam-
age and replace nozzle
set if necessary (see
chapter 9.1).
Replace air distribution
ring (see chapter 9.2).
EN
137