Mounting and Operating Instructions Doorguard hardwired version
4.3.1.2
Permanent release with automatic activation "special function" - S9 = ON:
Irrespective of parameterization when in deactivated state a operating >3 s switches the Doorguard in automa-
tic activation (One time release).
! The door then has to be opened during the door release time (15 s or 60 s selectable).
! The door can then remain open for any length of time without any reminder signal.
! Activation is performed automatically the first time the door is closed.
Flow chart: Permanent release with automatic activation
4.3.1.3
External input only for automatic activation (one time release) - S10 = ON:
One time release - typical Application: An employee is in a side room outside the protected area and want to go
back into the protected area - without an alarm is triggered. This is done by means of control via any key
operated switch or pushbutton using input (MG4).
! Operation via external input only for automatic activation possible.
! Stop the alarm and activation of the Doorgurard only with integrated key switch possible.
! Door lock release and door open time 15 s or 60 s (depend on programming).
! Activation is performed automatically the first time the door is closed.
! Input (MG 4) is monitored (12K1 in serial to pushbutton).
Duration of operation >200 ms.