8.

Technical data

8.1

Technical data - operating unit

Mains voltage
Frequency
Current consumption in normal mode
Voltage for external load +UB
Max. current for external load +UB
Mains voltage
Frequency
Detector group voltage
Detector group end-of-line resistor for open.cont
Detector group for tamper evaluation
Output for acoustical alarm signalling
Output for optical alarm signalling
Half cylinder as per DIN 18252
Operating temperature range
Storage temperature range
Environmental class as per VdS
Protection class as per EN 60529
Dimensions, operating module W x H x D
Housing colour
8.2

Technical data - alarm signalling device

Operating voltage range
Current consumption - acoustical alarm
Current consumption - optical alarm
Acoustical alarm signalling
Optical alarm signalling
Operating temperature range
Storage temperature range
Environmental class as per VdS
Protection class as per EN 60529
Dimensions, alarm signalling device W x H x D
Housing colour
The EU-Conformity Declaration can be downloaded under "www.honeywell.com/security/de" in the
Service/Download section.
Mounting and Operating Instructions Doorguard hardwired version
230 V AC
50 Hz
2.1 VA
ca. 18 V DC
70 mA
230 V AC
50 Hz
8 V DC
12K1 ±40%
12K1 ±40%
# 40 mA (active low)
# 40 mA (active low)
Standard dimension A = 30, A = 35 possible
-5 °C to +45 °C
-25 ° C to +70 ° C
II
IP 40
110 x 140 x 53 mm
traffic white (similar to RAL 9016)
9 V DC to 15 V DC
# 25 mA
# 25 mA
Loudness level approx. 100 dBA
LED - flash interval approx. 1.5 Hz
-5 °C to +45 °C
-25 ° C to +70 ° C
II
IP 40
110 x 103 x 53 mm
traffic white (similar to RAL 9016)