Mounting and Operating Instructions Doorguard hardwired version
3.2

Acoustical alarm

DIP switch 5
OFF
ON
3.3

Door release time monitoring

Various door monitoring possibilities as well as status and alarm functions are possible by combining the DIP
switches S6 and S7. The red LED "Activation" indicates the triggered state (Door open).
DIP switch 6
OFF
DIP switch 7
ON
(Condition on delivery from the factory)
ON
DIP switch 6
ON
DIP switch 7
DIP switch 6
ON
DIP switch 7
OFF
Irrespective of automatic activation, the state can be changed by an operating function at all times.
Switches for acoustical alarm
Acoustical alarm until clearing (manual stop using key-operated switch)
Acoustical alarm - 3 minutes (manual stop using key-operated switch possible)
Without reminder signal
The monitored door can be opened in the inactive state as often as required
and for as long as required
Manual operation
- With key
- Via external operating input
- Via corresponding key at disable and display module
- Activation is only possible when door is closed.
With reminder tone
- The door should not remain open without reminder for longer than 1 minute.
- After 1 minute, the opened door generates a short reminder tone every 20
seconds.
- The door can be opened repeatedly.
Manual operation
- With key
- Via external operating input
- Via corresponding key at disable and display module
- Activation is only possible when door is closed.
With reminder tone
- After 1st minute, when door is open a short reminder tone is emitted every
second.
- After the 2nd minute, a short reminder tone (double) is emitted.
- After the 3rd minute an alarm signal (continuous tone) is emitted.

Automatic activation

- Automatic activation 1 minute after inactivation, when the door is closed.
(The door can be opened within 1 minute after inactivation). If opened later an
alarm is emitted).
"One-time entry":
- Activation on closing
- Permissible release time without reminder tone, maximum 1 minute.
- Manual activation is possible.