46
4.3

Door open monitoring

Programming of the Doorguard takes place with the 12 DIP switches on the operating unit. By the
combination of DIP switch DIP S6 and DIP S7 as well as DIP S9 and DIP S10 various door open
monitoring states and alarm signalling modes are possible.
The DIP switches are only queried during initialization (when the operating voltage is ap-
plied). Therefore, the setting of this switch is only effective when energized! Wait before
re-applying the operating voltage for about 30 seconds.
4.3.1

Overview of DIP switch functions

DIP switch
Short description
of function
BUS address setting
S1 to S4
Time for acoustical messa-
S5
ge
S6
Door open signal
S7
Activation
S8
Network operating
S9
Door lock release during
operation >3s when deacti-
vated
Operation via external input
S10
Door lock release
S11
not used
S12
Irrespective of the automatic activation, the state can be changed at all times via an operating functi-
on.
4.3.1.1
Permanent release with manual activation "special function" - S9 = OFF:
Irrespective of parameterization when in deactivated state a operating >3 s switches the Doorguard to a per-
manent release. (Note: A short operating switches the Doorguard in the active state again).
! The door can be opened any number of times and remain open for any length of time.
! The permanent release is shown by the green LED when flashing symmetrical.
Flow chart: Permanent release with manual activation
Mounting and Operating Instructions Doorguard hardwired version
Off
until manual stop
without
automatically when the door
is closed
Slave
permanent release
Operation same as opera-
ting with integrated key
switch
60 seconds
not used
ON
max. 3 minutes
with
with manual operation
Master
automatic activation
(One time release)
Operating only for one
time door release
15 seconds
not used

Werbung