5 OPERATION

Supply voltage
Input current at maximum output
Maximum recommended fuse* or circuit breaker rating
*Time delay fuse UL class RK5, refer to UL 248
Maximum recommended fuse* or circuit breaker rating
*Normal operating UL class K5, refer to UL 248
Minimum recommended cord size
Maximum recommended extension cord length
Minimum recommended grounding conductor size
Supply from power generators
The power source can be supplied from different types of generators. However, some
generators may not provide sufficient power for the welding power source to operate
correctly. Generators with Automatic Voltage Regulation (AVR) or with equivalent or better
type of regulation, with rated power 8 kW, are recommended.
5
OPERATION
General safety regulations for handling the equipment can be found in the "SAFETY
PRECAUTIONS" chapter of this manual. Read it through before you start using the
equipment!
NOTE!
When moving the equipment use intended handle. Never pull on the cables.
WARNING!
Rotating parts can cause injury, take great care.
WARNING!
Electric shock! Do not touch the workpiece or the welding head during operation!
WARNING!
Assure that the side covers are closed during operation.
0463 408 001
120 - 230 V, 1 ~ 50/60 Hz
230 V AC
30 Amps
16 Amps
50 Amps
2
 4 mm
(12 AWG) 4 mm
15 m (50 ft)
2
4 mm
(12 AWG) 4 mm
- 14 -
120 V AC
30 Amps
30 Amps
50 Amps
2
(12 AWG)
8 m (25 ft)
2
(12 AWG)
© ESAB AB 2016