Herunterladen Inhalt Inhalt Diese Seite drucken

Inscriptions And Symbols On The Unit - Wetekom 90 45 16 Bedienungsanleitung

Digital multimeter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating Elements and Connections

Inscriptions and Symbols on the Unit

10 A
Input for measuring current in the ampere measuring
range up to 10 A - AC/DC. In the 10 A range the meas-
uring time must be limited to a maximum of 15 seconds
and the next measuring should happen no sooner than
after 15 minutes. This measuring range is not protected
by a fuse. If the current is higher than 10 A, the unit can
be destroyed.
A
Input for measuring current of up to 2 A - AC/DC. The
Input is fuse protected (F 2 A/250 V Ø 5 x 20 mm).
COM Earth Connection
~
AC (Alternating Current/Alternating Voltage)
DC (Direct Current/Direct Voltage)
Dangerously high voltage between the inputs. Use
extreme caution when taking a measurement. Do not
touch the inputs and the metal tips of the probes.
Attention! Please read the manual carefully!
CAT II Measuring Category 2
Protection Class II
Diode Test Function
Continuity Test Function
V
Voltage Measuring Function
A
Current Measuring Function
Resistance Measuring Function
25