  • DEUTSCH, seite 1
CAUTION
Unallowable combination of prosthetic components
Risk of injury due to breakage or deformation of the product
► Only combine the product with prosthetic components that are
approved according to the section "Combination possibilities".
► Based on the instructions for use of the prosthetic components,
verify that they may be combined with each other.
CAUTION
Excessive strain on the product
Risk of injury due to breakage of load-bearing components
► Use the prosthetic components according to the classification
(see section "Area of application").
NOTICE
Use under unallowable environmental conditions
Damage to product due to unallowable environmental conditions
► Do not expose the product to unallowable environmental condi­
tions (see the section "Environmental Conditions").
► If the product has been exposed to unallowable environmental
conditions, check it for damage.
► If damage is apparent or in case of doubt, do not continue using
the product.
► Take suitable measures if required (e. g. cleaning, repair,
replacement, inspection by the manufacturer or a specialist
workshop etc.).
Signs of changes in or loss of functionality during use
Among other factors, changes in functionality can be indicated by an
altered gait pattern, a change in the positioning of the prosthetic com­
ponents relative to each other and by the development of noises.

4 Scope of delivery

The following single components and accessories are included in the
scope of delivery in the specified quantities and are available for
reordering as single components ( ), single components with minim­
um order quantities (
) or single-component packs ( ):
2WR95, 2WR95=1 tube adapter, 4WR95=3 tube clamp adapter
Fig.
Item
Quant­
Designation
ity
1(   )
Instructions for use
1(   )
Adapter
4( 
 )
Set screw
For 4WR95=3
1(   )
Cap screw, titanium
1(   )
Plastic ring
1(   )
Clamping bolt
1(   )
Clamping bolt with
inner thread

5 Preparation for use

CAUTION
Incorrect alignment or assembly
Risk of injury due to damaged prosthetic components
► Observe the alignment and assembly instructions.
INFORMATION
► Only use the titanium cap screw at the end of the finishing pro­
cess for the prosthesis.
► Apply Loctite® to the titanium cap screw.
Reference num­
ber
506G3=M8x12-"­
Niro"
501T24=M5x25
4X28=3
4Y423
4Y424
Ottobock | 9

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

2wr95 14wr95 3

Inhaltsverzeichnis